- LT-4201M DIO Model (Sink Output Type)
- PFXLM4201TADDK
- 3.5"
Documentation
Support
Quick Information
Design Tools
Software
Certifications
Functional Specifications
Type | TFT Color LCD | ||
---|---|---|---|
Resolution (pixels) | 320 x 240 (QVGA) | ||
Active display area (W x H) | 70.56 x 52.92 mm (2.78 x 2.08 in.) | ||
Display Colors | 65,536 colors | ||
Backlight | White LED | ||
Non-exchangeable | |||
LED ON / OFF control, adjustable screen saver activation time | |||
Brightness adjustment | 16 levels of adjustment available via touch panel in the configuration menu | ||
Language Fonts *1 | Japanese, ASCII, Chinese (Simplified), Chinese (Traditional), Korean, Cyrillic, Thai | ||
Character sizes | 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts | ||
Font sizes | Width can be expanded 1 to 8 times. Height can be expanded 1/2 and 1 to 8 times. | ||
8 x 8 pixels | 40 characters per row x 30 rows | ||
8 x 16 pixels | 40 characters per row x 15 rows | ||
16 x 16 pixels | 20 characters per row x 15 rows | ||
32 x 32 pixels | 10 characters per row x 7 rows | ||
Memory | Application memory *2 | FLASH EPROM 16 MB (includes screen editing program and extended logic program) |
|
Logic program area | FLASH EPROM 132 KB *3 (equivalent to 15,000 steps) | ||
Font area | FLASH EPROM 8 MB (when limit exceeded, uses application memory) | ||
Data backup | nvSRAM 128 KB | ||
Variable area | nvSRAM 64 KB | ||
Touch Panel | Type | Resistive Film (analog) | |
Lifetime | 1 million touches or more | ||
Interface | Serial (COM1) | RS-232C/RS485 x 1 RS-232C (Connector type: RJ45, Isolation: None, Maximum baud rate: 115,200 bps, Cable Type: Shielded, Cable Maximum length: 15 m (49 ft), 5 Vdc power supply for RS-232C: None) RS-485 (Connector type: RJ45, Isolation: None, Maximum baud rate: 115,200 bps, Cable Type: Shielded, Cable Maximum length: 200 m (656 ft), Polarization: Setting is required via software when connecting Multiple LTs. Refer to the "GP-Pro EX Device/ PLC Manual" for the setting. 5 Vdc power supply for RS-485: None) *4 |
|
Ethernet | IEEE802.3 compliant Ethernet x 1 (Connector type: RJ45, Driver: 10 M half duplex (auto negotiation)/ 100 M full duplex (auto negotiation), Cable type: Shielded, Automatic cross-over detection: Yes) |
||
USB (Type A) | USB 2.0 (Type A) x 1 (Power Supply Voltage: 5Vdc +/-5%, Maximum Current Supplied: 500mA, Maximum Transmission Distance: 5m (16.4 ft.)) |
||
USB (Mini-B) | USB 2.0 (Mini-B) x 1 | ||
Control | DIO(Sink Type) | 20 Points Standard Input (including 2 Points for Fast Input) 10 Points Standard Output, 2 Points for Fast Output |
- *1 Please refer to the GP-Pro EX Reference Manual for details on font types and character codes.
- *2 Capacity available for user application.
- *3 Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
- *4 2-wire connection is available for RS-485. When a Device/PLC supports 2-wire connection, 4 wires (RXD+, TXD+, RXD-, and TXD-) can be short-circuited to be 2 wires (RXD+ and TXD+ = D1, RXD- and TXD- = D0). For details on the connection, refer to the connection manual.
Rated Input Voltage | 24 Vdc |
---|---|
Input Voltage Limits | 20 to 28.8 Vd |
Acceptable Voltage Drop | 10 ms or less at 20.4 Vdc |
Power Consumption | 9 W or less |
In-Rush Current | 30 A or less at 28.8 Vdc |
Voltage Endurance between power terminal and frame ground (FG) | 500 Vdc for 1 minute |
Insulation Resistance between power terminal and FG | 10 MΩ or higher at 500 Vdc |
Environmental Specifications
Standard compliance | IEC 61131-2 | |
---|---|---|
Ambient operating temperature for the display and the rear module | Horizontal installation | 0 to 50°C (32 to 122°F) |
Vertical installation | 0 to 40°C (32 to 104°F) | |
Storage temperature | - 20 to 60°C (- 4 to 140°F) | |
Storage altitude | 0 to 10,000 m (0 to 32,808 ft) | |
Operating altitude | 0 to 2,000 m (0 to 6,560 ft) | |
Surrounding Air and Strage Humidity | 5 to 85% w/o condensation (non-condensing, wet bulb temperature 39°C (102.2°F) or less) | |
Degree of pollution | IEC60664 | 2 |
Degree of protection | IEC61131-2 | IP20 with protective covers in place |
Corrosive gases | Free of corrosive gases | |
Dust | ≤0.1 mg/m3 (10-7 oz/ft3) (non-conductive levels) | |
Atmospheric pressure (Operating Altitude) | 800 to 1,114 hPa (2000 m (6,561 ft) or lower) | |
Vibration resistance | Mounted on a DIN rail | 3.5 mm (0.138 in.) fixed amplitude from 5 to 8.4 Hz 9.8 m/s2 (1 gn) fixed acceleration from 8.4 to 150 Hz |
Mounted on a panel | 3.5 mm (0.138 in.) fixed amplitude from 5 to 8.6 Hz 9.8 m/s2 (1 gn) fixed acceleration from 8.6 to 150 Hz |
|
Mechanical shock resistance | Mounted on a DIN rail | 147 m/s2 (15 gn) for a duration of 11 ms |
Mounted on a panel | 147 m/s2 (15 gn) for a duration of 6 ms | |
Electrostatic discharge | IEC/EN 61000-4-2 | 8 kV (air discharge) 6 kV (contact discharge) |
Rediated radio frequency electromagnetic fields | IEC/EN 61000-4-3 | 10 V/m (80 MHz to 3 GHz) |
Fast transients / Burst noise | IEC/EN 61000-4-4 | Power lines: 2 kV Digital I/O: 1 kV Relay outputs: 2 kV Ethernet line: 1 kV COM line: 1 kV CAN line: 1 kV |
Surge immunity | IEC/EN 61000-4-5 | Power supply: CM: 1 kV; DM: 0.5 kV Digital I/O: CM: 1 kV; DM: 0.5 kV Shielded cable: 1 kV CM = line-earth DM = line-line |
Conducted disturbances induced by radio-frequency fields | IEC/EN 61000-4-6 | 10 Veff (0.15 to 80 MHz) |
Mains terminal dusturbance voltage | EN 55011 (IEC/CISPR11) | 150 to 500 kHz, quasi peak 79 dBμV |
500 kHz to 30 MHz, quasi peak 73 dBμV | ||
Electric field strength | EN 55011 (IEC/CISPR11) | 30 to 230 MHz, quasi peak 10 m @40 dBμV/m |
230 MHz to 1 GHz, quasi peak 10 m @47 dBμV/m | ||
Vibration immunity (operating) | IEC 61131-2 | |
Protection structure | NEMA TYPE 4X (indoors, with panel embedded) | |
Protection (front module) | IP65f - (IEC 60529) | |
Protection (rear module) | IP 20 - (IEC 60529) | |
Shock immunity (operating) | IEC 61131-2 15 gn 11 ms |
|
Cooling method | Natural air circulation | |
Weight | 496 g (17.49 oz) | |
Color | Front module: PT404 Rear module: RAL 7032 | |
Material | Front module: PC/PBT Rear module: PC/PBT |
Digital Inputs
Digital Input Characteristics
Rated Current | 5 mA | |
---|---|---|
Inrush Values | Voltage | 30 Vdc |
Current | 6.29 mA max. | |
Input impedance | 4.9 kΩ | |
Input type | Sink/Source | |
Rated voltage | 24 Vdc | |
Maximum Allowable Voltage | 28.8 Vdc | |
Input limit values | ON Voltage | 15 Vdc or more (15 to 28.8 Vdc) |
OFF Voltage | 5 Vdc or less (0 to 5 Vdc) | |
ON Current | 2.5 mA or more | |
OFF Current | 1.0 mA or less | |
Isolation | Method | Photocoupler Isolation |
Between internal logic | 500 Vdc | |
Filtering | 0.5 ms to 30.0 ms | |
IEC61131-2 edition 3 type | Type 1 | |
Compatibility | Supports 2 wire and 3 wire sensors | |
Cable type and length | Shielded: Maximum 100 m (328 ft) Non-shielded: 50 m (164 ft) |
|
Terminal blocks | Type: 3.5 mm (0.137 in.) pitch Terminal blocks are removable |
|
Input paralleling | No |
* I0 and I1 are Fast input terminals and can be also used as a Standard input. For specifications, see the specifications of Fast Input.
High Speed Counter Input Characteristics
Rated Current | Voltage | 24 Vdc | |
---|---|---|---|
Current | 7.83 mA | ||
Inrush values | Voltage | 30 Vdc | |
Current | 9.99 mA | ||
Input impedance | 3.2 kΩ | ||
Input type | Sink/Source | ||
Rated voltage | 24 Vdc | ||
Maximum Allowable Voltage | 28.8 Vdc | ||
Input limit values | ON Voltage | 15 Vdc or more | |
OFF Voltage | 5 Vdc or less | ||
ON Current | 5 mA or more | ||
OFF Current | 1.5 mA or less | ||
Isolation |
Method | Photo coupler Isolation | |
Between channels logic | 500 Vdc | ||
Filtering | None, 4 μs, 40 μs | ||
IEC61131-2 edition 3 type | Type 1 | ||
Compatibility | Supports 2 wire and 3 wire sensors | ||
Cable | Type | Shielded | |
Length | Maximum 10 m (33 ft) | ||
Terminal blocks | Type: 3.5 mm (0.137 in.) pitch Terminal blocks are removable |
||
Maximum frequency | · 100 kHz is the maximum frequency for Single-phase · 50 kHz is the maximum frequency for 2-phase · Duty Rate: 45 to 55% |
||
Phase Counting Mode | · Single phase · 2 Phase x2 · 2 Phase x4 · 2 Phase x2 Reverse · 2 Phase x4 Reverse |
||
Response time | Marker | 1 ms | |
Preload | 1 ms | ||
Prestrobet | 1 ms | ||
Synchronize output | 2 ms | ||
Min. Pulse Width(Pulse input) | Counter: |
Pulse Catch |
|
Input paralleling | No |
Digital Outputs
Transistor Output Characteristics
Rated Voltage | 24Vdc | |
---|---|---|
Output range | 19.2 to 28.8 Vdc | |
Output type | Sink | |
Rated current | 0.3 A/point, 3.0 A/common | |
Residual voltage | 1.5 Vdc or less for I= 0.1A | |
Delay |
Off to on (0.3 A load): 1.1ms |
|
Isolation | Method | Photocoupler Isolation |
Between internal logic | 500 Vdc | |
Minimum resistor load | 80 Ω at 24 Vdc | |
Cable length | Non-shielded: 150 m (492 ft) | |
Protection against short circuit | No | |
Terminal blocks |
Type: 3.5 mm (0.137 in.) pitch |
(1) When connecting as power surges
* To use 3.0A common current, connect to A3 and A4 for V1+. (B3 and B4 for V1-)
Caution: Q0 and Q1 circuits are push-pull circuits. The following is the operation of the push-pull circuit at the Sink Output and the Source Output. Sink Output: +24(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off Source Output: 0(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off Standard Output terminals Q2 or later are common open collector outputs. Do not connect Fast Output terminals Q0, Q1 and Standard Output terminals Q2 or later. It will short. If you add a manual circuit to terminal Q0, Q1, isolate the manual circuit and terminal Q0, Q1 with a relay. Without isolation, it will short. |
Pulse Output/PWM Output/High-speed Counter (Synchronize Output) Characteristics
Output type | Sink | ||
---|---|---|---|
Rated voltage | 24 Vdc | ||
Power supply input range | 19.2 to 28.8 Vdc | ||
Power supply reverse protection | Yes | ||
Pulse Output/PWM output current | 50 mA/point, 100 mA/common | ||
Response time for original input |
2 ms |
||
Isolation resistance | Between fast outputs and internal logic | 10 MΩ or more | |
Between power supply port and protective earth ground (PE) = 500 Vdc | 10 MΩ or more | ||
Residual voltage | for I = 0, 1 A | 1.5 Vdc or less | |
Delay | Off to on (50 mA load): 1.1ms On to off (50 mA load): 1.1ms NOTE: The delay is not including the cable delay. |
||
Minimum load impedance | 80 Ω | ||
Maximum Pulse output frequency | 50 KHz | ||
Maximum PWM output frequency |
65 kHz |
||
Accuracy Pulse Output/ PWM Output | Frequency | Accuracy | Duty |
10 to 1000 Hz | 1% | 1 to 99% | |
1.001 to 20 kHz | 5% | 5 to 95% | |
20.001 to 45 kHz | 10% | 10 to 90% | |
45.001 to 65 kHz | 15% | 15 to 85% | |
Duty rate range | 1 to 99% | ||
Cable | Type |
Shielded, including 24 Vdc power supply |
|
Length | Maximum 5 m (16 ft) | ||
Terminal blocks |
Type: 3.5 mm (0.137 in.) pitch |
Caution: Q0 and Q1 circuits are push-pull circuits. The following is the operation of the push-pull circuit at the Sink Output and the Source Output. Sink Output: +24(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off Source Output: 0(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off Standard Output terminals Q2 or later are common open collector outputs. Do not connect Fast Output terminals Q0, Q1 and Standard Output terminals Q2 or later. It will short. If you add a manual circuit to terminal Q0, Q1, isolate the manual circuit and terminal Q0, Q1 with a relay. Without isolation, it will short. |
Terminal Blocks
Pin Arrangement | Group | Pin | Signal Name | Group | Pin | Signal Name |
---|---|---|---|---|---|---|
Fast Output | A1 | V0+ | Fast Output | B1 | V0- | |
A2 | Q1 | B2 | Q0 | |||
Standard Output | A3 | V1+ | Standard Output | B3 | V1- | |
A4 | V1+ | B4 | V1- | |||
A5 | Q3 | B5 | Q2 | |||
A6 | Q5 | B6 | Q4 |
Pin Arrangement | Group | Pin | Signal Name | Group | Pin | Signal Name |
---|---|---|---|---|---|---|
Standard Output | C1 | Q7 | Standard Output | D1 | Q6 | |
C2 | Q9 | D2 | Q8 | |||
C3 | Q11 | D3 | Q10 | |||
Fast Input/Standard Input | C4 | I0 | Fast Input/Standard Input | D4 | IC0 | |
C5 | I1 | Standard Input | D5 | I2 | ||
Standard Input | C6 | I3 | D6 | IC1 | ||
C7 | I5 | D7 | I4 | |||
C8 | I7 | D8 | I6 | |||
C9 | I9 | D9 | I8 | |||
C10 | IC2 | D10 | IC2 | |||
C11 | I11 | D11 | I10 | |||
C12 | I13 | D12 | I12 | |||
C13 | I15 | D13 | I14 | |||
C14 | I17 | D14 | I16 | |||
C15 | I19 | D15 | I18 |
External Dimensions
Panel Cut-out
* If rotating torque acted on a display module is 2.5 N.m (22.12 in-lb) or more, use an anti-rotation tee which is supplied with a LT unit. The anti-rotation tee supports up to 6 N.m (53.10 in-lb). |