- GP4621TAA
- PFXGP4621TAA
- PFXGP4621TAAC
- 12.1"

Documentation

Support

Quick Information

Software

Certifications
Functional Specifications
Display Size | 12.1"
|
---|---|
Resolution | 800 x 600 pixels (SVGA)
|
Effective Display Area | W246.0 x H184.5 mm [W9.69 x H7.26 in.]
|
Display Colors | 65,536 colors (No blink) / 16,384 colors (Blink)
|
Backlight | White LED (Not user replaceable. When replacement is required, contact your local distributor.)
|
Backlight Service Life | 50,000 hrs. or more (each in continuous operation at 25 °C [77 °F] before backlight brightness decreases to 50%)
|
Language Fonts | Japanese: 6,962 (JIS Standards 1 & 2) (including 607 non-kanji characters), ANK: 158 (Korean, Traditional Chinese, Simplified Chinese, Thai and Cyrillic can be added from the font setting of the screen editor. )
|
Character Sizes | Standard font: 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts, Stroke font: 6 to 127 pixel fonts, Image font: 8 to 72 pixel fonts
|
Font Sizes | Standard font: Width can be expanded up to 8 times. Height can be expanded up to 8 times.*1
|
8 x 16 dots | 100 char. x 37 rows
|
16 x 16 dots | 50 char. x 37 rows
|
32 x 32 dots | 25 char. x 18 rows
|
8 x 8 dots | 100 char. x 75 rows
|
Program Area | FLASH EPROM 132 KB (Equivalent to 15,000 steps)*2
|
Variable Area | SRAM 64 KB (Replaceable Lithium battery for backup memory)
|
Application Memory | FLASH EPROM 32 MB (including a logic program area)
|
Data Backup | SRAM 320 KB (Replaceable Lithium battery for backup memory)
|
Clock Accuracy | ±65 sec./month (deviation at room temperature and power is OFF)*3
|
Touch Panel Type | Resistive Film (analog)
|
Touch Panel Resolution | 1,024 x 1,024
|
Touch Panel Service Life | 1,000,000 times or more
|
Serial (COM1) | Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: D-Sub 9 (plug)
|
Serial (COM2) | Asynchronous Transmission: RS-232C, Data Length: 7 or 8 bits, Stop Bit: 1 or 2 bits, Parity: None, Even or Odd, Data Transmission Speed: 2,400 to 115,200 bps, Connector: 2-piece terminal block 9 pin
|
Ethernet (LAN) | IEEE802.3i / IEEE802.3u, 10BASE-T / 100BASE-TX, Connector: Modular jack (RJ-45) x 1
|
Expansion Unit 1 | Video unit x 1
|
USB (TYPE-A) | Conforms to USB 2.0 (Type A) x 1
Power supply voltage: 5 Vdc ±5 % Output Current: 500 mA or less Communication distance: 5 m [16.4 ft.] or less |
USB (mini-B) | Conforms to USB 2.0 (mini-B) x 1, Communication Distance: 5 m [16.4 ft] or less
|
SD Card | SD Card Slot x 1
|
1Other font sizes can be set up with the Editor software.
2Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
3Depending on the operating temperature and age of unit, the clock can deviate from -380 to +90 sec./month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.
General Specifications
International Safety Standards | ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Rated Input Voltage | 100 to 240 Vac
|
Input Voltage Limits | 85 to 264 Vac
|
Rated Frequency | 50 / 60 Hz
|
Rated Frequency Range | 47 to 63 Hz
|
Allowable Voltage Drop | 1 cycle or less (Voltage drop interval must be 1 second or more.)
|
Power Consumption | 100 Vac: 56 VA or less, 240 Vac: 77 VA or less
|
In-Rush Current | 30 A or less
|
Voltage Endurance | 1,500 Vac, 20 mA for 1 minute (between charging and FG terminals)
|
Insulation Resistance | 500 Vdc, 10 MΩ or more
|
Surrounding Air Temperature | 0 to 55 °C [32 to 131 °F]*4
|
Storage Temperature | -20 to +60 °C [-4 to 140 °F]
|
Ambient Humidity | 10 to 90 % RH (Wet bulb temperature: 39 °C [102.2 °F] max. - no condensation)
|
Storage Humidity | 10 to 90 % RH (Wet bulb temperature : 39 °C [102.2 °F] max. - no condensation)
|
Dust | 0.1 mg/m3 (10-7 oz/ft3) or less (non-conductive levels)
|
Pollution Degree | For use in Pollution Degree 2 environment
|
Air Pressure (altitude range) | 800 to 1,114 hPa (2,000 m [6,561 ft.] above sea level or less)
|
Vibration Resistance | IEC/EN 61131-2 compliant
5 to 9 Hz single amplitude 3.5 mm [0.14 in.] 9 to 150 Hz fixed acceleration: 9.8 m/s2 X, Y, Z directions for 10 cycles (approx. 100 min.) |
Concussion Resistance | IEC/EN 61131-2 compliant 147 m/s2, X, Y, Z directions for 3 times
|
Noise Immunity | Noise Voltage : 1,000 Vp-p
Pulse Duration : 1 µs Rise Time : 1 ns (via noise simulator) |
Electrostatic Discharge Immunity | Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)
|
Grounding | Functional grounding: Grounding resistance of 100 Ω, 2mm2 (AWG 14) or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
|
Structure | IP65f NEMA #250 TYPE 4X/13 (on the front panel when properly installed in an enclosure)*5*5
|
Cooling Method | Natural air circulation
|
Weight Approx. | 2.5 kg [5.5 lb] or less
|
External Dimensions | W207.8 x H153.2 x D59.8 mm [W8.18 x H6.03 x D2.35 in.]
|
Panel Cut Dimensions | W301.5 x H227.5 mm [W11.87 x H8.96 in.]
Panel thickness area: 1.6 to 5 mm [0.06 to 0.2 in.]**6 |
4Surrounding Air Temperature of the Video Unit is 0 to 50 °C (32 to 122 °F) when attaching the Video Unit to GP-4621T.
5The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested. Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP unit, be sure to confirm the type of conditions that will be present in the GP's operating environment. If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.
6Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.]. Even if the installation wall thickness is within the recommended range for the "Panel Cut Dimensions", depending on wall's material, size, and installation location of GP unit and other devices, the installation wall could warp. To prevent warping, the installation surface may need to be strengthened.
External Dimensions


Panel Cut-Out

A | B | C | R |
301.5 mm (+1, -0 mm) (11.87 [+0.04, -0 in]) |
227.5 mm (+1, -0 mm) (8.96 in. [+0.04, -0 in]) |
1.6 to 5 mm (0.06 to 0.2 in) | 3 mm (0.12 in.) maximum |
External Dimensions with Cables