Pro-face IoT Gateway Compatible Driver / Tested HMI

Gateway Mode compatible drivers

Manufactures Drivers
Mitsubishi Electric Corporation A Series CPU Direct
Q Series CPU Direct
FX Series CPU Direct
A Series Computer Link
QnA Series CPU Direct
Q/QnA Serial Communication
FX Series Computer Link
OMRON Corporation C/CV Series HOST Link
CS/CJ Series HOST Link
FANUC LTD. Power Mate Series
Fuji Electric Co.,Ltd. MICREX-SX Series SIO
YASKAWA Electric Corporation MEMOBUS SIO
TOSHIBA MACHINE CO., LTD. TC Series (TCmini/TC200)
Panasonic Industrial Devices SUNX Co., Ltd. FP Series Computer Link SIO
Yokogawa Electric Corporation Personal Computer Link SIO
KEYENCE Corporation KV Series CPU Direct
KV-700/1000/3000/5000 CPU Direct
Siemens AG SIMATIC S5 3964
SIMATIC S7 3964/RK512
Hitachi, Ltd. S10 Series SIO
Modbus-IDA General MODBUS SIO Master

There are restrictions below for use of the gateway mode. Please make sure of operation before use.
- When a specific connected device made by Mitsubishi Electric Corporation has a configuration of communication type 1, the gateway mode cannot be used.
- If the gateway mode is used when a connected device has CPU direct configuration, the communication speed might get slower.

See the restrictions.

For communication tools.

Operation-tested HMIs

HMI Pro-face IoT Gateway (GP-4G01)
Gateway Mode Driver
RS-232C RS-422 Cable Diagram PDF
Mitsubishi Electric Corporation
GOT1000
Mitsubishi A Series CPU Direct Cable Diagram M-6 Cable Diagram M-2 Download
(PDF: 308KB)
Mitsubishi A Series Computer Link Cable Diagram M-8 *3 Cable Diagram M-7 *3
Mitsubishi Q Series CPU Direct Cable Diagram M-6 -
Mitsubishi Q/QnA Serial Communication Cable Diagram M-6 *3 Cable Diagram M-7 *3
Mitsubishi QnA Series CPU Direct - Cable Diagram M-2 *4
Mitsubishi FX Series CPU Direct Cable Diagram M-5 Cable Diagram M-4
OMRON C/CV Series HOST Link Cable Diagram M-1 Cable Diagram M-4
OMRON CS/CJ Series HOST Link Cable Diagram M-1 *1 Cable Diagram M-4 *1
KEYENCE Corporation
VT2
Mitsubishi A Series Computer Link Cable Diagram K-6 *3 Cable Diagram K-5 *3 Download
(PDF: 353KB)
Mitsubishi Q Series CPU Direct Cable Diagram K-4 -
Mitsubishi Q/QnA Serial Communication Cable Diagram K-4 Cable Diagram K-5
Mitsubishi QnA Series CPU Direct - Cable Diagram K-5
Mitsubishi FX Series CPU Direct Cable Diagram K-4 Cable Diagram K-5
Mitsubishi FX Series Computer Link Cable Diagram K-4 *3 -
OMRON C/CV Series HOST Link Cable Diagram K-3 *2 Cable Diagram K-5 *2
OMRON CS/CJ Series HOST Link Cable Diagram K-3 *1 Cable Diagram K-5 *1
Keyence KV Series CPU Direct Cable Diagram K-4 -
Keyence KV-700/1000/3000/5000 CPU Direct Cable Diagram K-4 Cable Diagram K-5
OMRON Corporation
NS12-TS01-V1
Mitsubishi A Series Computer Link Cable Diagram O-2 *3 - Download
(PDF: 290KB)
Mitsubishi Q/QnA Serial Communication Cable Diagram O-1 -
Mitsubishi FX Series Computer Link Cable Diagram O-1 *3 -
OMRON C/CV Series HOST Link Cable Diagram O-1 -
OMRON CS/CJ Series HOST Link Cable Diagram O-1 *1 -
Hakko Corporation
V810iS
Mitsubishi A Series CPU Direct - Cable Diagram H-3 Download
(PDF: 308KB)
Mitsubishi A Series Computer Link Cable Diagram H-4 Cable Diagram H-2
Mitsubishi Q Series CPU Direct Cable Diagram H-1 -
Mitsubishi Q/QnA Serial Communication Cable Diagram H-1 -
Mitsubishi FX Series CPU Direct Cable Diagram H-5 Cable Diagram H-2
Mitsubishi FX Series Computer Link Cable Diagram H-5 *3 Cable Diagram H-2 *3
OMRON C/CV Series HOST Link Cable Diagram H-1 Cable Diagram H-2
OMRON CS/CJ Series HOST Link Cable Diagram H-1 Cable Diagram H-2

*1 When the target PLC is CS/CJ series, you need to select [OMRON C/CV series HOST Link] for the communication protocol of GP-4G01.

*2 Able to connect by using the communication driver of GP-Pro EX Ver. 4.07.200. Unable to connect when GP-Pro EX with an earlier version than Ver. 4.07.200 is used.

*3 Able to connect by using the communication driver of GP-Pro EX Ver. 4.08.000. Unable to connect when GP-Pro EX with an earlier version than Ver. 4.08.000 is used.

*4 Able to connect by using the communication driver Ver. 1.14.08 or later. Please download the latest version of it from our Web site.

In addition to the above HMIs, when another HMI's operation is confirmed, the list is updated accordingly.